Chapter 1 - Product Description Specifications
BreezeMAX PRO 5000 CPE 9 Product Manual
1.3.8 Physical and Electrical
1.3.8.1 Mechanical
1.3.8.2 Electrical
1.3.8.3 Connectors
Table 1-8: Mechanical Specifications
Unit Dimensions (cm) Weight (kg)
CPE-IDU 156mm (L) X 60mm (W) X 33mm (T) or
95mm(L) X 57mm (W) X 32mm (T)
0.3
0.2
CPE-ODU-PRO-SA 230mm (H) X 230mm (W) X 63mm (T) 2
Table 1-9: Electrical Specifications
Item Details
Power Consumption 16.5W
CPE-IDU Power Input 100-240 VAC, 47-63 Hz
CPE-ODU-PRO Power Input 54 VDC (or 48VDC) from the IDU over the indoor-outdoor Ethernet
cable
Table 1-10: Connectors
Unit Connector Details
CPE-IDU-1D ETHERNET/LAN 10/100Base-T (RJ-45).Cable connection to a PC:
StraightCable connection to a hub: Crossed
RADIO/LAN+DC 10/100Base-T (RJ-45)
AC IN 3 pin AC power plug
CPE-ODU-PRO-SA IDU COM 10/100Base-T (RJ-45)
SAU Special mini USB