User's Manual
Table Of Contents
- BreezeMAX Extreme System Manual
- About This Manual
- Contents
- System Description
- 1.1 About WiMAX
- 1.2 WiMAX Network Architecture
- 1.3 BreezeMAX Extreme
- 1.4 Specifications
- Installation
- 2.1 BTS Installation
- 2.2 GPS Installation
- 2.3 Indoor Power Supply Installation
- 2.4 Cable Connections
- 2.5 External Antennas Connection
- Commissioning
- Operation and Administration
- 4.1 BreezeMAX Extreme System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 The Main Menu
- 4.5 BTS Menu
- 4.5.1 Show Summary
- 4.5.2 Show Properties
- 4.5.3 Configuration
- 4.5.4 Unit Control
- 4.5.4.1 Change Password
- 4.5.4.2 Reset BTS
- 4.5.4.3 Reset to BTS Factory Defaults
- 4.5.4.4 SW Version Control
- 4.5.4.5 Configuration File Control
- 4.5.4.6 Monitor Inactivity Timeout
- 4.5.5 Fault Management
- 4.5.6 Performance Counters
- 4.6 ASN-GW Menu
- 4.6.1 AAA
- 4.6.2 Services Menu
- 4.7 Sector Menu
- 4.8 BS Menu
- 4.9 Radio Channel Menu
- 4.10 Antenna Menu
- 4.11 GPS Menu
- 4.12 MS Menu
- 4.13 Parameters Summary
- Glossary
Chapter 4 - Operation and Administration Parameters Summary
BreezeMAX Extreme 178 System Manual
Sector Location Up to 64 printable characters Null Yes
Sector Heading 0-359 (degrees) 0 Yes
Bandwidth
5 MHz (not supported by some 5.4
GHz Band Names)
10 MHz
10 MHz No
Frequency Depends on supported frequency band
and configured Bandwidth. In 5 GHz units
depend also on Band Name.
Depends on
supported frequency
band. In 5 GHz units
depend also on Band
Name.
No
Tx Power Depends on unit type. In 5 GHz units
depend also on Band Name and Antenna
Gain.
Depends on unit type.
In 5 GHz units
depend also on Band
Name and Antenna
Gain.
No
DFS (5 GHz units using a Band Name supporting DFS)
DFS Support
Enable
Disable
Enable No
Channel Availability Check
Time
0-600 seconds 60 seconds No
Channel Non Occupancy
Period
0-60 minutes 30 minutes No
Startup Test Valid Period 0-48 hours 6 hours No
Radar Detection Threshold -36 to -70 dBm EIRP>30 dBm: -67
EIRP=23-30 dBm:-64
EIRP<23 dBm: -62
No
BS - General Parameters
BS Name Up to 32 printable characters Null Yes
BS - MAC
Segment Number 0-3 0 No
Cell Number 0-31. For cells with 4 sectors the range is
0-17.
0No
Table 4-21: BTS Parameters Summary
Parameter Range Default Run-Time
Updated