User's Manual
Table Of Contents
- BreezeMAX Extreme System Manual
- About This Manual
- Contents
- System Description
- 1.1 About WiMAX
- 1.2 WiMAX Network Architecture
- 1.3 BreezeMAX Extreme
- 1.4 Specifications
- Installation
- 2.1 BTS Installation
- 2.2 GPS Installation
- 2.3 Indoor Power Supply Installation
- 2.4 Cable Connections
- 2.5 External Antennas Connection
- Commissioning
- Operation and Administration
- 4.1 BreezeMAX Extreme System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 The Main Menu
- 4.5 BTS Menu
- 4.5.1 Show Summary
- 4.5.2 Show Properties
- 4.5.3 Configuration
- 4.5.4 Unit Control
- 4.5.4.1 Change Password
- 4.5.4.2 Reset BTS
- 4.5.4.3 Reset to BTS Factory Defaults
- 4.5.4.4 SW Version Control
- 4.5.4.5 Configuration File Control
- 4.5.4.6 Monitor Inactivity Timeout
- 4.5.5 Fault Management
- 4.5.6 Performance Counters
- 4.6 ASN-GW Menu
- 4.6.1 AAA
- 4.6.2 Services Menu
- 4.7 Sector Menu
- 4.8 BS Menu
- 4.9 Radio Channel Menu
- 4.10 Antenna Menu
- 4.11 GPS Menu
- 4.12 MS Menu
- 4.13 Parameters Summary
- Glossary
Chapter 4 - Operation and Administration BTS Menu
BreezeMAX Extreme 89 System Manual
4.5.5.1.4 Suppression Interval
The Suppression submenu includes the following options:
Show Modified Traps (Suppression Interval Changed): Displays all traps
with a modified Suppression Interval (the default for all traps is 0).
Update: Enables modifying the Suppression Interval parameter of a selected
trap. The available range is from 0 to 86,400 (seconds). The default is 0, which
means no suppression.
Restore Suppression Interval Defaults: Enables restoring the Suppression
Interval parameter of all traps to the default value (0, meaning no
suppression).
4.5.5.2 Show Active Alarm Log Table
Select to view the currently active alarms. For each active alarm, the following
details are displayed:
Seq#: The sequential identification number of the event (trap).
Time: The Date and Time at which the alarm was generated.
MO Type & Instance: The Type and Instance (ID number) of the applicable
Managed Object.
Event Type: The type of event (first level of event description).
Probable Cause: The probable cause of the event (second level of event
description).
Specific Problem: The specific problem that caused the event (third level of
event description).
Alarm Severity: The defined severity of the Alarm.
Object Severity: The combined events severity for the Managed Object at the
time at which the alarm was generated.