Quick Installation Guide

Table Of Contents
BreezeMAX Extreme Base Transceiver Station Quick Installation Guide
P/N 215790
- 6 - January 2011
CAUTION:
Do not connect two power sources (PoE and DC input) simultaneously.
Connecting the Cables to the BTS
The BreezeMAX Extreme is provided with sealing glands on all the cable connectors. The DATA/DC IN/OUT, and GPS IN/OUT
cables are to be connected to the BTS by inserting the cable connector through the sealing gland. The DC power cable is
supplied with a sealing gland that should replace the existing sealing gland provided with the BTS. For the GPS ANT connector,
a weather-proof metal cap seals the connection. If this connector is not used, do not remove the metal cap. In case there is only
a rubber cap on this connector, use additional sealing methods to protect this connection.
A dedicated tool is supplied for fastening the sealing glands.
Figure 9: BTS with Sealing Gland and Gland Fastening Tool
Figure 10: BTS Connections (Bottom View)
Grounding Cable
Connect a grounding cable between the ground terminal of the BTS (marked ) and a good ground connection. Connect the RF
connector (marked
) to the antenna. The RF connectors should be properly sealed to protect against rain and moisture.
Data/PoE Cable
1. Remove the DAT
A DC IN/OUT sealing gland from the BTS.
2. Open the sealing gland and thread the cable through the gland's nut.
3. Carefully insert the cable with the already assembled RJ-45 connector through the sealing gland.
4. Connect the cable to the DATA connection on the BTS.
5. Return the sealing gland. Use the dedicated tool to fasten it.
6. Use the dedicated tool to fasten nut on the sealing gland body.
7. Connect the other end of the cable to one of the following:
If you are using PoE (for 5 GHz units only) - to the PoE AC/DC power supply RJ-45 connector (labeled as
Radio). Connect the Ethernet port of the PoE PS to the backhauling equipment using a standard Ethernet
cable. Connect the PoE PS to the 110/220 VAC mains. The combined lengths of the Ethernet cables should
not exceed 100m.
If you are not using PoE – directly to the backhauling equipment.
DC Power Cable (not applicable if using PoE)
1. Remove the existing gland from the 48V connection on the BTS
2. Attach the DC power cable with the already assembled sealing gland to the 48V connection on the BTS.
3. Separate the sealing gland’s nut from the gland body.
4. Use the dedicated tool to fasten the gland to the BTS.
5. Use the dedicated tool to fasten the sealing gland's nut on the gland body.
6. Connect the other end of the power cable to the 48V DC power source.
External Antenna Cable
1.
Connect one end of the coax
ial RF cable to the connector (marked ) located on the rear panel of the unit.
2. Connect the other end of the RF cable to the antenna.