Installation Manual
Table Of Contents
- Cover
- 01_Description
- 02_Installation
Chapter 1 - System Description Specifications
BreezeMAX Extreme 32 System Manual
Protection:
The protection mechanism meets ETSI EN 300 132-2 requirements. No damage is
caused to the equipment under the following conditions:
» Overvoltage: input disconnection when voltage is higher than 60VDC in
steady state.
» Undervoltage: input disconnection when voltage is lower than 36VDCin
steady state.
» Inverse voltage polarity: input disconnection on inverse input voltage
polarity.
Output short circuit when BTS feeding self-backhaul element: output
disconnection on the circuit short.
Transmit power levels at antenna connector as
function of Chanel bandwidth and
ante
nna type (BreezeMAX Extreme 5.4 Base station, 5470 MHz – 5725 MHz
Table 1-22:
Antenna type RF chains/CH BW Transmitted power
(dbm)
Sector, 17dbi 1RF chain /5MHz 7.7
Sector, 17dbi 2RF chains/5MHz 4.7
Sector, 17dbi 1RF chain /10MHz 10.7
Sector, 17dbi 2RF chains/10MHz 7.7
Internal, 15.5dbi 1RF chain /5MHz 8.5
Internal, 15.5dbi 2RF chains/5MHz 8.5
Internal, 15.5dbi 1RF chain /10MHz 11.5
Internal, 15.5dbi 2RF chains/10MHz 11.5
Omni, 8dbi 1RF chain /5MHz 16.7
Omni, 8dbi 2RF chains/5MHz 13.7
Omni, 8dbi 1RF chain /10MHz 19.7
Omni, 8dbi 2RF chains/10MHz 16.7