Installation Manual

Table Of Contents
Chapter 1 - System Description Specifications
BreezeMAX Extreme 29 System Manual
1.5.6 Environmental
The outdoor equipment in operation complies with ETSI 300 019-2-4 Class T4.1E
requirements.
The indoor equipment in operation complies with ETSI 300 019-2-3 Class 3.2
requirements.
Table 1-16: Outdoor Equipment Environmental Specification
Item Description
Low Operating Temperature -40ºC (IEC-68-2-1) cold start is required.
High Operating Temperature +60
º
C (IEC-68-2-2).
Temperature change 0.5
º
C / minute between -40
º
C to +60
º
C (IEC-68-2-14).
Humidity 5 to 95% none condensation. (IEC-60068-2-56).
Rain (ETSI 300 019-2-4), IP-67
Random Vibration according to ETSI 300 019-2-4 V2.2.2 (2003) T4.1E.
Shock according to ETSI 300 019-2-4 V2.2.2 (2003) T4.1E
Salt Fog IEC68-2-11Ka
Solar Radiation (IEC-68-2-5), MIL-STD-810D.
Wind speed survival 220Km/hr (CS3)
Wind speed operational 160Km/hr. (CS3) for operating stability.
Ice loading (CS-3) 25mm radial ice density 7kN/m
3
Table 1-17: Indoor Equipment Environmental Specification
Item Description
Low Operating Temperature -5
0
C (IEC-68-2-1)
High Operating Temperature 45
0
C (IEC-68-2-2)
Temperature change -5 45
0
C (IEC-68-2-14).
Humidity (IEC-68-2-56).
Random Vibration (IEC 68-2-64).
Shock (IEC-68-2-27).