User Manual
Table Of Contents
- BreezeMAX® Extreme
- System Manual
- About This Manual
- Contents
- System Description
- 1.1 About WiMAX
- 1.2 WiMAX Network Architecture
- 1.3 BreezeMAX Extreme
- 1.4 Specifications
- 1.4.1 General Modem & Radio
- 1.4.2 3.x GHz BTS
- 1.4.3 5 GHz BTS
- 1.4.4 Sensitivity
- 1.4.5 3.x GHz Antennas
- 1.4.6 5 GHz Antennas
- 1.4.7 Power Supply
- 1.4.8 GPS Antennas
- 1.4.9 Data Communication (Ethernet Port)
- 1.4.10 Configuration and Management
- 1.4.11 Environmental
- 1.4.12 BTS Standards Compliance, General
- 1.4.13 Notes on Maximum Tx Power Limitations for 5 GHz Units:
- Installation
- 2.1 BTS Installation
- 2.2 GPS Installation
- 2.3 Indoor Power Supply Installation
- 2.4 Cable Connections
- 2.5 External Antennas Connection
- Commissioning
- Operation and Administration
- 4.1 BreezeMAX Extreme System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 The Main Menu
- 4.5 BTS Menu
- 4.5.1 Show Summary
- 4.5.2 Show Properties
- 4.5.3 Configuration
- 4.5.4 Unit Control
- 4.5.5 Fault Management
- 4.5.6 Performance Counters
- 4.6 ASN-GW Menu
- 4.6.1 AAA
- 4.6.2 Services Menu
- 4.6.2.1 Common Operations in Services Menus
- 4.6.2.2 MSs Services
- 4.6.2.3 Service Profiles
- 4.6.2.4 QoS Profiles
- 4.6.2.5 Multiple Service Flows
- 4.6.2.6 Service Rules
- 4.6.2.7 Classifiers
- 4.6.2.8 Service Groups
- 4.6.2.9 Service Interfaces
- 4.6.2.9.1 Service Interface ID
- 4.6.2.9.2 Service Interface Name
- 4.6.2.9.3 Forwarding Rule Name
- 4.6.2.9.4 CS Type
- 4.6.2.9.5 VLAN Interface
- 4.6.2.9.6 VLAN Transparency
- 4.6.2.9.7 VLAN ID
- 4.6.2.9.8 VLAN Priority Marking
- 4.6.2.9.9 VLAN Priority
- 4.6.2.9.10 VLAN List
- 4.6.2.9.11 Inner DSCP Marking
- 4.6.2.9.12 Inner DSCP
- 4.6.2.10 Forwarding Rules
- 4.7 Sector Menu
- 4.8 BS Menu
- 4.9 Radio Channel Menu
- 4.10 Antenna Menu
- 4.11 GPS Menu
- 4.12 MS Menu
- 4.13 Parameters Summary
- Glossary
Chapter 3 - Commissioning Configuring Parameters Required for Remote Management
BreezeMAX Extreme 53 System Manual
3.1 Configuring Parameters Required for
Remote Management
After completing the installation process, as described in the preceding chapter,
some parameters must be configured using either Telnet (the Monitor application)
or AlvariCRAFT. These parameters are necessary to enable remote management of
the BTS.
Refer to Chapter 4 for information on how to access the Monitor application and
how to use it. Refer to the AlvariCRAFT User Manual for information on how to
use it.
The basic parameters are listed in Table 3-1. Refer to Chapter 4 for detailed
information on the applicable parameters.
NOTE
AlvariCRAFT can be used only if the Authorized Managers list in the BTS is either empty (default) or
includes the IP address of the AlvariCRAFT station.
Table 3-1: Basic BTS Parameters
Management Option Parameters
BTS-Connectivity
IP address
Subnet Mask
Default Gateway
VLAN ID
VLAN Priority
Authorized Managers
(per manager)
IP Address
Read Community
Write Community
Traps Distribution Enabled