Chapter 4 - Operation and Administration BTS Menu
BreezeMAX Extreme 90 System Manual
4.5.5.1.2 Distribution Enabled
The Distribution Enabled submenu includes the following options:
Show Distribution Disabled Traps: Displays all traps with Distribution
Enabled parameter set to Disable (the default for all traps is Enable).
Update: Enables modifying the Distribution Enabled parameter of a selected
trap.
Restore Distribution Enabled Defaults: Enables restoring the Distribution
Enabled parameter of all traps to the default value (Enable).
4.5.5.1.3 Alarm Severity
The Alarm Severity option is applicable only for Alarm traps.
The Alarm Severity submenu includes the following options:
Show Modified Traps (Severity Changed): Displays the current and default
Severity for all Alarm traps with modified Severity (different from the default).
Update: Enables modifying the Severity parameter of a selected Alarm trap.
The available options are Indeterminate, Critical, Major, Minor, Warning.
Restore Severity Defaults: Enables restoring the default Severity parameter
of all traps to the default value.
4.5.5.1.4 Suppression Interval
The Suppression Interval submenu includes the following options:
Show Modified Traps (Suppression Interval Changed): Displays all traps
with a modified Suppression Interval (the default for all traps is 0).
Update: Enables modifying the Suppression Interval parameter of a selected
trap. The available range is from 0 to 86,400 (seconds). The default is 0, which
means no suppression.
Restore Suppression Interval Defaults: Enables restoring the Suppression
Interval parameter of all traps to the default value (0, meaning no
suppression).