User Manual

Table Of Contents
Chapter 4 - Operation and Administration BTS Menu
BreezeMAX Extreme 89 System Manual
Event Log Selection Criteria
Show Event Log Table By Selection Criteria
Show All Event Log Table
4.5.5.1 Trap Configuration
The Trap Configuration menu enables viewing current parameters of all traps and
updating the parameters of a selected trap. It also enables viewing traps with
modified parameters (different from the default) and restoring the configuration of
all modified traps to their default values.
The available options are:
Show
Distribution Enabled
Alarm Severity
Suppression Interval
4.5.5.1.1 Show
Select this option to view a list of all traps and their parameters. For each trap,
the following details are displayed:
Trap ID
Name
Distribution Enabled (the default for all traps is Enabled)
Suppression Interval (in seconds. The default is 0, which means no
suppression).
Default Severity*
Current Severity*
* The Severity parameter is applicable only for Alarm traps. It is not applicable to
other trap categories (System Event, Configuration Change Event).