User's Manual
Table Of Contents
- BreezeMAX Extreme System Manual
- About This Manual
- Contents
- System Description
- 1.1 About WiMAX
- 1.2 WiMAX Network Architecture
- 1.3 BreezeMAX Extreme
- 1.4 Specifications
- Installation
- 2.1 BTS Installation
- 2.2 GPS Installation
- 2.3 Indoor Power Supply Installation
- 2.4 Cable Connections
- 2.5 External Antennas Connection
- Commissioning
- Operation and Administration
- 4.1 BreezeMAX Extreme System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 The Main Menu
- 4.5 BTS Menu
- 4.5.1 Show Summary
- 4.5.2 Show Properties
- 4.5.3 Configuration
- 4.5.4 Unit Control
- 4.5.5 Fault Management
- 4.5.6 Performance Counters
- 4.6 ASN-GW Menu
- 4.7 Sector Menu
- 4.8 BS Menu
- 4.9 Radio Channel Menu
- 4.10 Antenna Menu
- 4.11 GPS Menu
- 4.12 MS Menu
- 4.13 Parameters Summary
- Glossary

Chapter 4 - Operation and Administration ASN-GW Menu
BreezeMAX Extreme 113 System Manual
Service Rule ID
Service Interface Name
4.6.2.6.1 Service Rule ID
This is an auto-sequential number from 1 to a maximum of 4, generated
automatically during creation of a new Service Rule for a specific Multiple Service
Flow.
4.6.2.6.2 Service Interface Name
The Name of the Service Interface associated with the Service Rule. Must be one of
the previously defined Service Interfaces that exists in the database.
4.6.2.7 Classifiers
The Classifiers submenu option for a selected Service Rule enables managing the
Classifier(s) assigned to the Service Rule. At least one Classifier must be assigned
to each Service Rule, up to a maximum of five Classifiers per Service Rule.
Note the following rules when either defining a new Classifier or updating an
existing one:
A maximum of one Classifier of type Any for a certain direction can be
associated with each MS. This means:
» A Service Rule can include a maximum of one Classifier of type Any for a
certain direction.
» A Multiple Service Flow can include a maximum of one Service Rule with a
Classifier of type Any for a certain direction.
» An MS can have a maximum of one Service associated with a Multiple
Service Flow with a Service Rule with a Classifier of type Any for a certain
direction.
Overlapping of range values is not allowed. This is applicable for:
» The Service Rule level: The range values defined for any Classifier of a
certain Type for a certain direction assigned to a Service Rule should not
overlap with the range values of other Classifiers of the same Type for the
same direction assigned to the same Service Rule.
» The Multiple Service Flow level: The range values defined for any Classifier
of a certain Type for a certain direction assigned to a Service Rule of a