Appendix C. DS.11 FAQ
BreezeNET BU-DS.11/RB-DS.11 C-3 User’s Guide
Can I downgrade my DS.11 firmware?
Yes, an earlier version of firmware can overwrite a newer version.
Can I keep the previous version of firmware? No and yes. The previous version of
firmware can not be kept on the DS.11 itself, but can be stored on your PC and loaded
if needed.
Does DS.11 support 802.1Q VLAN?
Yes, but the support is limited to transparent operation. Meaning, DS.11 does not take
any action on 802.1Q frames, but will transparently pass them within a VLAN network.
Can I change the regulatory domain (country) of my DS.11?
No. The regulatory domain is factory set.
How can I configure or manage my DS.11 if I forgot the SNMP Community name?
Press the reset button on the back panel with a paper clip. This will set the read and
write Community names to public and private, respectively.
How can I return the DS.11 unit to factory default settings?
There are two ways. One way is to use the Default button on the Station Control Tab in
the DS.11 Manager Utility. The other is to press and hold the reset button on the back
of the unit while powering on the unit. Remember that all settings including IP
addresses will be lost when setting defaults.
Can I use the BreezeNET PI-CAT5 product with my DS.11 unit?
No. The PI-CAT5 is specifically for the PRO.11 units only. The voltage is not the
same between the two devices.
Can I place the BU-DS.11/RB-DS.11 DS.11 unit outdoors?
No, not directly. The BU-DS.11/RB-DS.11 is specified to operate at 0°C to 40°C and
is not weather proof. It is best to mount the DS.11 indoors or in a protective cabinet.
Can I use the ODB-1 product with my DS.11 unit?
No. The ODB-1 is specifically for the PRO.11 units only.