User's Guide
Installation
User's Guide 2-20 BreezeNET BU-DS.11/RB-DS.11
Note: If the power cord supplied with the unit is open ended, connect to it a power plug appropriate to
the country in which the unit is being installed. The color codes of the cable are:
brown phase ~
blue neutral 0
yellow/green grounding
The operating AC mains voltage of the Indoor unit is marked on the rear panel of the unit.
3. After connecting the Outdoor unit to the Indoor unit using the Indoor-to-Outdoor cable,
connect the power cord to the unit’s AC outlet, located on the rear panel shown in Figure 2-7.
Connect the other end of the power cord to the AC mains.
100-120VAC
207-253VAC 250mA
500mA
Figure 2-7. Indoor Unit Rear Panel
4. Verify that the POWER LED located on the rear panel lights Green, indicating that the unit
self-test passed and that 48 VDC output to the Outdoor unit is not shorted.
10-BASE-T
RADIO
RESET
LINK
POWER
Figure 2-8. Indoor Unit Front Panel
5. Connect the 10-BASE-T connector to the network. The cable connection should be straight.
Note: The length of the Ethernet cable connecting the Indoor unit to the user's equipment, together
with the length of the Indoor-to-Outdoor cable, should not exceed 100 meters.
2.8.1 Verifying Correct Operation of the Indoor Unit
To verify proper operation, view the LED indicators located on the rear panel of the outdoor unit as
shown in Figure 2-8, and as described in Table 2-5.
Table 2-5. Indoor Unit LEDs
Name Description Functionality