User's Guide

Installation
BreezeNET BU-DS.11/RB-DS.11 2-17 User’s Guide
2.7.3 Verifying Correct Operation of the Outdoor Unit
To verify proper operation, view the LED indicators located on the bottom panel of the outdoor unit
as shown in Figure 2-4.
Table 2-4 lists the various LED states.
Table 2-4: Outdoor Unit LEDs
Name Description Functionality
WLAN Wireless Link Blinking Green Data received or transmitted
on wireless link
Green No data on link
DC Power Self Test and
Power indication
Green Self test passed and 12VDC power is
supplied to the unit
Red Self test failed and 12VDC is not
available
ETH Ethernet activity Green Ethernet link is operational, with no
traffic on the port.
Blinking Green Ethernet link is operational,
with traffic on the port.
Red No Ethernet link.
RSSI Bar
on
RB-DS.11
units
Series of LEDs
Displays the RSSI (Received Signal Strength
Indication, or the received RF signal level) at the
Outdoor radio unit, as follows:
Bar0 (red) -91dBm
Bar1 (green) -87dBm
Bar2 (green) -83dBm
Bar3 (green) -80dBm
Bar4 (green) -77dBm
Bar5 (green) -74dBm
Bar6 (green) -71dBm
Bar7 (green) -66dBm
Bar8 (green) -61dBm
-
55dBm