User's Guide
Installation
BreezeNET BU-DS.11/RB-DS.11 2-3 User’s Guide
2. Mount the Outdoor unit and the external antennas (optional). Connect the Outdoor unit to the
antenna if installing external antennas.
Note: The FCC 15.203 requirement prohibits the connection of external antennas with standard N-
type connectors. In order to meet this requirement, the external antenna connectors provided on
DS.11D models (with no integral antenna) are non-standard, featuring left-handed (counter-
clockwise) rotation.
3. Connect a ground cable between the Outdoor unit and an appropriate grounding point.
4. Connect the Indoor-to-Outdoor cable to the Outdoor unit and route it to the location selected
for the Indoor unit. Assemble the enclosed connector on the cable. Refer to Appendix B for
instructions on preparing the Indoor-to-Outdoor cable.
5. Mount the Indoor unit. Connect the Indoor-to-Outdoor cable to the Indoor unit Radio port.
Prepare the power cable and use it to connect the Indoor unit to the AC mains.
6. Connect the Indoor unit Ethernet port to the user’s network/PC using an Ethernet cable.
7. Align the antenna and verify connectivity with the Base Station.
Note: The Indoor unit should be connected to the power source only after it has been connected to the
Outdoor
unit.