14 Acceptance Testing
14.1 Headend Equipment Testing
14.1.1 BTS Output Measurement
The BTS/Node B output power should be adjusted so that the UDC output port will have a 0 dBm per
carrier.
The UDC is factory configured to have 20 dB attenuation, therefore the BTS/Node B output should be
the following.
Example for GSM BCCH should be 20 dBm, BTS has 46 dBm composite power.
Number of Carriers Attenuation at BTS
Output (downlink only)
Measured Composite
(after attenuator)
1 26 dB 20 dBm
2 23 dB 23 dBm
4 20 dB 26 dBm
8 17 dB 29 dBm
No. Test Operations Test Requirement
Results
Pass Fail
1 Measure BTS/Node B output See 1.1
14.1.2 UDC Testing
1. For each UDC verify that all three LEDs are green
2. Measure the Pilot signal (962 MHz) at the UDC DL out port. The signal should be 0 ± 1 dBm.
3. Measure the cellular downlink signal at the UDC DL out port. The signal should be 0 ± 1 dBm.
No. Test Operations Test Requirement
Results
Pass Fail
1 Examine UDC LEDs All LEDs are Green
2 Measure Pilot signal (962 MHz) 0 ± 1 dBm
3 Measure Cellular signal 0 ± 1 dBm