User's Manual Part 2

BreezeCOMPACT System Manual
Chapter 4 - Operation and AdministrationBS Menu
Chapter 4 - Operation and Administration BS Menu
116
A change in Maximum Cell Radius will take effect after next reset.
4.7.2.5.4 Ducting Mitigation Mode
Not supported in the current release.
4.7.2.6 Connectivity
The Connectivity menu includes the following options:
Bearer Interface
Authentication
QOS Marking Rules
ASN-GW Load Balancing
4.7.2.6.1 Bearer Interface
The Bearer Interface menu enables viewing/updating the values configured for the following
parameters:
IP Address
Default Gateway Connectivity Status
4.7.2.6.1.1 IP Address
The IP address of the bearer interface of the BS. Must be unique in the network.
A change in Bearer IP Address will take effect after next reset.
4.7.2.6.1.2 Default Gateway Connectivity Status
Read-only. The status of connectivity with the default authenticator: unknown, up, down. The keep-alive
mechanism starts only after first registration at the ASN-GW. Until then this mechanism is disable and
connectivity status is unknown.
4.7.2.6.2 Authentication
The Authentication menu enables viewing/updating the values configured for the following parameter:
4.7.2.6.2.1 Threshold - Active MSs
The threshold for the number of MSs in active operation state (not Idle) served by the BS. Exceeding this
threshold sets the alarm “Excessive MS number”.
The range is 0-1024. When set to 0, the alarm is disabled. The default is 1024.
4.7.2.6.3 QOS Marking Rules
The QoS Marking Rules menu includes the following options:
Internal ASN Traffic QOS Rules
Internal Management Traffic QOS Rules
QOS Rules