User's Manual Part 2

BreezeCOMPACT System Manual
Chapter 4 - Operation and AdministrationBTS Menu
Chapter 4 - Operation and Administration BTS Menu
92
The IP address of the TFTP Server holding the SW file to be loaded is defined by the TFTP Server
parameter (see “Configuration Files Control” on page 93). You will be prompted to enter the File Path
And File Name (up to 50 characters) and to confirm the requested operation.
4.5.3.2.4 Reset and Run from Shadow
Select the Reset and Run from Shadow option to reset the BTS and run the Shadow version after power
up. To avoid unintentional actions you will be prompted to confirm the request.
4.5.3.2.5 Set Running Version As Operational
When the BTS is running the Shadow version (after selecting Reset and Run from Shadow), it will boot
from the Operational version after the next reset. Select the Set Running Version As Operational option
if you want to swap versions so that the running version will become the Operational version and will be
the version to be used after reset. To avoid unintentional actions you will be prompted to confirm the
request.
4.5.3.3 ShutDown Operation
The ShutDown Operation submenu enables selecting one of the following options:
shutdown: Select this option to shut down the system. To avoid unintentional shut down, you will
be prompted to confirm the request.
reset: Select this option to reset the BTS. To avoid unintentional reset, you will be prompted to
confirm the reset request. Changes to some of the configurable parameters are applied only after
reset.
resettoFactoryDefault: Select this option to restore the factory default configuration of all BTS
parameters. All parameters will revert to their default values after the next reset. To avoid
unintentional action, you will be prompted to confirm the request.
noAction: Select this option to exit the Shutdown Operation submenu without any action.
resettoFactoryDefaultwithConnectivity: Select this option to restore factory default configuration
without changing any of the parameters required for maintaining management connectivity to the
unit. To avoid unintentional action, you will be prompted to confirm the request.
NOTE!
Before shutting down the system, it is recommended that you save the configuration file. The last saved
configuration is used for rebooting the system.
After shutting down the system you cannot restart it from remote. To start up the unit (after shut
down), switch off and then switch on the power supply to the unit.
NOTE!