Chapter 3 - CommissioningConfiguring Parameters Required for Management Connectivity
Chapter 3 - Commissioning Configuring Parameters Required for Management Connectivity
70
Configure the required Port Speed. Note that for Port Number 1 only 1000 Mbps is supported.
Configure the required Duplex Mode.
3.2.5 Configuring the SNMP Authorized Manager and Traps
Manager
3.2.5.1 Configuring the Authorized Manager
By default the unit is supplied with one SNMP Traps Manager with the following parameters:
Manager Number: 1
Community Read Only: public
Community Read and Write: private
If different communities are used by the management system, you should add an SNMP Authorized
Manager with the correct communities or update the existing one.
To add an Authorized Manager select BTS>Management>Authorized Managers>Add. You will be
prompted to configure the Manager Number, the Community Read Only and the Community Read and
Write.
To update the default Authorized Manager, select BTS>Management>Authorized Managers>Select, at
the Manager Number prompt enter 1 and select the Update option. You will be prompted to configure
the Community Read Only and the Community Read and Write.
3.2.5.2 Configuring the SNMP Traps Manager
By default the unit is supplied with one SNMP Traps Manager with the following parameters:
IP Address: 192.168.1.60
Port Number: 162 (this is the default port number used by the management system)
Community: public
Enable Traps Distribution: enable
If different parameters are used by the management system, you should add an SNMP Traps Manager
with the correct parameters (the IP Address of an existing SNMP Traps Manager cannot be updated).
To add an SNMP Traps Manager select BTS>Management>SNMP Traps Managers>Add. You will be
prompted to configure the IP Address, the Port Number, the Community and the Enable Traps
Distribution parameter.
3.2.6 Applying the Configuration
To apply the changes, reset the unit (select BTS>Unit Control>Shutdown operation>Update and select
the reset option).
After the unit reboots, it should be discoverable and manageable from remote by the EMS station.