User's Manual Part 2
BreezeCOMPACT System Manual
Chapter 2 - BreezeCOMPACT InstallationConnecting the BreezeCOMPACT Cables
Chapter 2 - BreezeCOMPACT Installation Connecting the BreezeCOMPACT Cables
58
2.7.5 Preparing and Connecting the Power Cable
The power cable is supplied either crimped with a connector or open ended. If the cable is open-ended,
use the procedure below to prepare it for connection, depending on the supplied cable type (4-wire or
6-wire).
Cable type (for already crimped cables): Outdoor 4 wires 16AWG shielded. Two wires are connected
to -48VDC, two wires are connected to return signal and 1 wire to the Ground.
Connector type: 6-pin mini-fit.
Maximum power consumption:105W (average, without PoE), 125W (peak, without PoE)
A readily accessible disconnect device is incorporated external to the equipment.
1 Make sure you have the following components:
» Outdoor shielded 4x16AWGpower cable
» Five terminals for Mini-Fit 16 AWG wires
» Mini-fit 6-pin housing that fits the terminals
» A crimping tool for preparing the wires, suitable for 20-16 AWG/0.1-1.5 mm
2
wires with open
barrel terminals. It is recommended to use the Samtec CAT-HT-169-1620-11.
2 Insert the cable through the sealing gland.
3 Remove as small a length as possible of the cable's external jacket to expose the wires.
4 Insert a terminal into the appropriate Pressmaster slot.
5 Insert the wire into the terminal within the slot and squeeze the tool's handles to crimp the terminal.
INFORMATION
The combined lengths of the Ethernet cables should not exceed 100m.
To prepare the power cable:
Figure 2-24: Open Barrel Terminal