User's Manual

Table Of Contents
Installing the Si CPE
BreezeMAX CPEs Product Manual 45
2 Verify that the orange Status LED located on the unit's top
panel illuminates, indicating that the power supply to the unit is OK and the
unit is not yet connected to a Base Station (the LED will change to green when
the unit is connected to a Base Station).
3 If a detached antenna is used, remove the cap on the unit's top panel to expose
the RF connector and connect to it the RF cable supplied with the antenna.
Install the antenna using the instructions provided in Section 2.4 on page 42,
and connect to it the other end of the RF cable. To tighten the SMA connectors,
use only the torque key supplied with the antenna.
4 Configure the basic parameters as described in Section 3.3.1.
5 Align the antenna as described in Section 3.5.
6 For E model units: Connect the 10/100 Base-T ETHERNET connector to the
data equipment. The cable connection should be a crossed Ethernet if
connecting to a hub/switch and a straight cable if connecting directly to a PC
Network Interface Card (NIC).
Verify proper operation of the Ethernet link. The Ethernet Integrity green LED
should be on and the Ethernet Activity yellow LED should blink when there is
Ethernet traffic. To verify data connectivity from the end-user's PC or from a
portable PC connected to the unit, ping a known device in the network, or try
connecting to the Internet.
For U model units: Use a USB cable to connect the USB connector on the unit
to the USB connector of the data equipment. If needed, install the USB driver
provided with the unit. Refer to the README file in the USB driver installation
CD supplied with the unit.
2.3.5.2 Wall Mounting the Si CPE
The wall mounting kit for the Si CPE includes a bracket, 2 screws, and 2 plastic
anchors. Refer to Figure 2-14.
1 If anchors are needed (wall-board, plaster board, etc.), drill two holes for the
anchors using a 6 mm drill bit and insert anchors. The distance between the
NOTE
The color codes of the power cable are as follows:
Brown
Phase ~
Blue Neutral 0
Yellow/Green Ground