User's Manual
Table Of Contents
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - Products Description
- 1.1 BreezeMAX CPEs
- 1.2 Introducing BreezeMAX PRO-S CPE
- 1.3 Introducing BreezeMAX Si CPE
- 1.4 Voice and Networking Gateways
- 1.5 PRO-S CPE Specifications
- 1.6 Si CPE Specifications
- Chapter 2 - Installation
- 2.1 Installing the ODU of the PRO-S CPE
- 2.2 Installing the IDU-1D Indoor Unit of the PRO-S CPE
- 2.3 Installing the Si CPE
- 2.4 Installing the 3.5 GHz Detached Antenna
- 2.5 Installing the 2.3/2.5 GHz Detached Antenna
- Chapter 3 - Commissioning
- Chapter 4 - Operation
- 4.1 The SU Installer Monitor Program
- 4.2 Using the Monitor Program
- 4.3 The Main Menu
- 4.4 Unit Control Menu
- 4.5 Registration Parameters Menu
- 4.6 BST/AU ID Parameters Menu
- 4.7 ˘Radio Parameters Menu
- 4.8 Multirate and ATPC Parameters Menu
- 4.9 Performance Monitoring Menu
- 4.10 FDD Parameters (3.x GHz units only)
- 4.11 ˘SU Parameters Summary
- Appendix A - The Web Configuration Server
- Appendix B - Troubleshooting
- Glossary
90 Operation
Chapter 4 - Operation
4.4.5.3.3 Configuration File Upload Name
Select this option to enter the name in the TFTP server directory of the
configuration file to be uploaded. A Configuration File Upload Name consists of up
to 50 characters.
The default Configuration File Upload Name is SU_UPLOAD_CFG.
4.4.5.3.4 Perform Configuration Upload
Select this option to execute the configuration file upload operation. To avoid
unintentional actions you will be prompted to confirm the request.
1 Typically it is recommended to configure the IP address of the PC to
192.168.254.250, which is the default TFTP Server IP address of the unit. If a
different IP address is configured in the PC with the TFTP server, configure the
TFTP Server IP address to the same address.
2 Enter the name of the configuration file (as will appear in the TFTP server) as
the Configuration File Upload Name.
3 Select Perform Configuration Upload and confirm the dupload request. Wait to
receive a success/failure message.
4.4.6 Ethernet Port Operation Mode
The Ethernet Port Control parameter enables viewing and defining the operation
mode of the Ethernet port
The available options are:
Show Ethernet Mode
Set Ethernet Mode
NOTE
When the SU is synchronized with a base station, it receives the TFTP Server IP Address from the
base station during the network entry process. This address is 1.7.1.1 for a Base Station (NPU)
and 1.1.1.1 for a Micro Base Station. This will be the TFTP Server IP Address after each reset, as
long as the SU is associated with a base station.
The same TFTP Server IP Address parameter is used in the SW Download, Configuration File
Download and Configuration File Upload processes.
To perform configuration file upload: