User's Manual
Table Of Contents
- BreezeMAX CPEs Product Manual
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - Products Description
- Chapter 2 - Installation
- 2.1 Installing the ODU of the PRO-S CPE
- 2.2 Installing the IDU-1D Indoor Unit of the PRO-S CPE
- 2.3 Installing the Si CPE
- 2.4 Installing the 3.5 GHz Detached Antenna
- 2.5 Installing the 2.3/2.5 GHz Detached Antenna
- Chapter 3 - Commissioning
- Chapter 4 - Operation
- 4.1 The SU Installer Monitor Program
- 4.2 Using the Monitor Program
- 4.3 The Main Menu
- 4.4 Unit Control Menu
- 4.5 Registration Parameters Menu
- 4.6 BST/AU ID Parameters Menu
- 4.7 ˘Radio Parameters Menu
- 4.8 Performance Monitoring Menu
- 4.9 Multirate and ATPC Parameters Menu
- 4.10 ˘SU Parameters Summary
- Appendix A - The Web Configuration Server
- Appendix B - Troubleshooting
- Glossary
Si CPE Specifications
BreezeMAX CPEs Product Manual 15
1.6 Si CPE Specifications
1.6.1 Radio
Table 1-12: Si CPE Radio Specifications
Item Description
Frequency Band TDD Frequencies (MHz) FDD Frequencies (MHz)
2.3 GHz 2305-2360 Not Applicable
2.5 GHz g 2496-2690 Not Applicable
3.5 GHz 3399.5-3600 Uplink: 3399.5-3500
Downlink: 3499.5-3600
Operation Mode
TDD, Half Duplex
FDD, Half duplex (3.5 GHz band only)
Channel Bandwidth
1.75 MHz (only in FDD mode in the 3.5 GHz band)
3.5 MHz
5 MHz (only in TDD mode)
Central Frequency
Resolution
0.125 MHz
Antenna Port SMA, 50 ohm
Internal Antennas (Si) A beam switching array of 6 x 60° antennas.
Antenna gain: 7 dBi for 2.3/2.5 GHz units, 9 dBi for 3.5 GHz units
External Antenna Port SMA, 50 ohm
Max. Input Power
(at antenna port)
-20 dBm before saturation
0 dBm before damage
Output Power
(at antenna port)
22 dBm +/- 1 dB maximum
ATPC Dynamic range: 46 dB
Modulation Downlink: OFDM; Uplink: OFDMA-16
BPSK, QPSK, QAM16, QAM64
FEC Convolutional Coding: 1/2, 2/3, 3/4