BreezeMAX CPEs Product Manual 121
Authentication Failure:
STATUS LED is blinking
green, SIGNAL LED 7 is
on, all other SIGNAL LEDs
are off.
Authentication problem:
a. Wrong User Name
and/or User Password.
b.Maximum number of
Multiple Sessions (number
of SUs that can receive the
Service simultaneously)
has been reached.
Enter User Name and User Password and reset the
unit. If the problem persists, contact the operator.
Duplicate Name: STATUS
LED is blinking green,
SIGNAL LEDs 6 and 7 are
on, all other SIGNAL LEDs
are off.
User Name already exists
in the Base Station’s
database, associated with
another SU (MAC address)
Enter a correct User Name or contact the operator
for a new User Name/Password. Reset the unit after
configuring new authentication parameters.
Authentication Timeout:
STATUS LED is blinking
green, SIGNAL LEDs 5, 6
and 7 are on, all other
SIGNAL LEDs are off.
The unit was not
reauthenticated after
authentication timeout.
Contact the operator.