30 BreezeMAX CPEs Product Manual
Chapter 2 - Installation
lightly squeeze the cap. Carefully insert the cable with the assembled
connector through the groove.
2 Connect the Ethernet cable to the IDU COM RJ-45 connector.
3 Put the sealing cap back in its place. Make sure that the small protrusion on
the side of the cap fits inside the hole on the connector's protective body.
4 Use
appropriate sealing material to protect the connection against moisture
and humidity. Use removable sealing material, such as a tar seal, to enable
future access to the connector.
5 Route the cable to the location selected for the indoor equipment.
6 Assemble an RJ-45 connector with a protective cover on the indoor end of the
IDU-ODU cable. Refer to the pin assignment and color codes in standard
cables described above.
Figure 2-7: Inserting the IDU COM
Cable into the Sealing Cap
Figure 2-8: Connecting the IDU COM connector and inserting the Sealing Cap