User's Manual
Table Of Contents
- BreezeMAX CPEs Product Manual
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - Products Description
- Chapter 2 - Installation
- 2.1 Installing the ODU of the PRO-S CPE
- 2.2 Installing the IDU-1D Indoor Unit of the PRO-S CPE
- 2.3 Installing the Si CPE
- 2.4 Installing the 3.5 GHz Detached Antenna
- 2.5 Installing the 2.3/2.5 GHz Detached Antenna
- Chapter 3 - Commissioning
- Chapter 4 - Operation
- 4.1 The SU Installer Monitor Program
- 4.2 Using the Monitor Program
- 4.3 The Main Menu
- 4.4 Unit Control Menu
- 4.5 Registration Parameters Menu
- 4.6 BST/AU ID Parameters Menu
- 4.7 ˘Radio Parameters Menu
- 4.8 Performance Monitoring Menu
- 4.9 Multirate and ATPC Parameters Menu
- 4.10 ˘SU Parameters Summary
- Appendix A - The Web Configuration Server
- Appendix B - Troubleshooting
- Glossary
SU Parameters Summary
BreezeMAX CPEs Product Manual 105
Scanning End Frequency Depend on Radio Band and
Bandwidth
Yes
(after Update
Scanning
Table
Scanning Main Step Depend on opetration mode
(FDD/TDD) and Bandwidth
875 KHz Yes
(after Update
Scanning
Table
Scanning Intermediate Steps
Bits 0 -7
0 or 1 (Disable/Enable) for
each of the 8 Intermediate
Steps (Bits)
0 for all Bits Yes
(after Update
Scanning
Table
Discrete Frequencies Up to 10. Available
frequencies depend on
Radio Band and Bandwidth.
Null (empty list) Yes
(after Update
Scanning
Table
Rx Attenuator
(2.3 GHz units)
0, 10 (dB) 0
Multirate and ATPC Parameters
Set Tx Power PRO-S CPE: -26 to 20 dBm
using 1 dBm resolution.
Si CPE: -26 to 22 dBm using
1 dBm resolution.
Last power used by
ATPC
Yes
Table 4-2: SU Parameters Summary
Parameter Range Default Run-Time
Updated