User's Manual

Table Of Contents
Configuring Basic Parameters
BreezeMAX CPEs Product Manual 59
3.2 Configuring Basic Parameters
3.2.1 The Basic Parameters
Table 3-1: SU's Basic Parameters
Parameter Default Value Comment
Ethernet Port auto Negotiation
Enable/Disable
Enabled Applicable only to E-model units (with
Ethernet interface).
Ethernet Port Speed and Duplex Applicable only to E-model units (with
Ethernet interface). Applicable only if
Ethernet Port Auto Negotiation
Enable/Disable is set to Disable
User Name Null Must be supplied by system administrator
User Password Null Must be supplied by system administrator
Organization Name Optional - according to administrator policy
Address Optional- according to administrator policy
Country Optional- according to administrator policy
BST/AU ID 186.190.0.0.250.206
BST/AU ID ID Mask 255.255.255.0.0.0
Best BST/AU Support Disable
Preferred BST/AU ID
Preferred BST/AU ID Mask
Bandwidth 3.5 MHz
Antenna (Si CPE only) 3 (internal, oppsite to
the connectors' side)
Scanning Start Frequency Depend on Radio
Band and Bandwidth
Scanning End Frequency Depend on Radio
Band and Bandwidth
Scanning Main Step 875 KHz
Scanning Intermediate Steps
Bits 0 to 7
0 for all eight bits
Discrete Frequencies