User Manual

Table Of Contents
Installing the IDU-1D Indoor Unit of the PRO-S CPE
BreezeMAX CPEs Product Manual 33
2.2 Installing the IDU-1D Indoor Unit of the
PRO-S CPE
2.2.1 Installation Requirements
2.2.1.1 Packing List
BMAX-CPE-IDU-1D
Wall mounting kit
Mains power cord
2.2.1.2 Additional Installation Requirements
Ethernet cable(s): a crossed cable if connecting to a hub/switch and a straight
cable if connecting directly to a PC Network Interface Card (NIC).
Mains plug adapter or termination plug (if the power plug on the supplied AC
power cord does not fit local power outlets).
Means for configuring parameters:
A Portable PC/Notebook and a straight Ethernet cable for configuring
parameters using Telnet. TFTP server SW is required for downloading SW
versions.
Or:
A Portable PC/Notebook or Pocket PC/PDA and a straight Ethernet cable
for configuring parameters using a web browser.
NOTE
The IDU must be ordered separately. It is not supplied with the ODU.
NOTE
The length of the Ethernet cable connecting CPE-IDU-1D to the user's equipment, together with the
length of the IDU-ODU cable, should not exceed 100 meters.