28 Installation
Chapter 2 - Installation
2.1.4.3 Pole Mounting the ODU with the Tilt Accessory
1 Attach the Tilt accessory to the ODU using the two pairs of flat washers, spring
washers and nuts supplied in the Tilt kit.
2 Mount the Tilt accessory on a 1" to 4" pole using two 9/16" metal bands.
3 Release slightly the Tilt Control Screw, tilt the ODU downward/upward as
required, and re-tighten the screw.
Figure 2-4: ODU Pole Installation Using the Tilt Accessory, Vertical Polarization
To mount the ODU on a pole using the Tilt accessory: