User Manual
Chapter 4 - Operation and Administration Using the CLI Managing AUs
4Motion 472 System Manual
4.5.3.1 Restoring the Default Values of Properties Parameters
To restore the some or all of the Properties parameters to their default value, run
the following command:
npu(config-au-1)# no properties [required-type] [required-ports]
[required-bandwidth] [port-1-power] [port-2-power] [port-3-power]
[port-4-power]
You can restore only selected parameters to their default value by specifying only
those parameter. For example, to restore only the required type to the default
value (threeDSP), run the following command:
npu(config-au-1)# no properties required-type
The parameter will be restored to its default value, while the other parameters will
remain unchanged.
To restore all properties parameters to their default value, run the following
command:
npu(config-au-1)# no properties
4.5.3.2 Restoring the Default Value of the Control Parameter
To restore the Control parameter to the default value (normalOperation), run the
following command:
npu(config-au-1)# no control
NOTE
Refer to Section 4.5.2.1 for a description and default values of these parameters.
Command
Syntax
npu(config-au-1)# no properties [required-type] [required-ports]
[required-bandwidth] [port-1-power] [port-2-power] [port-3-power]
[port-4-power]
Privilege
Level
10
Command
Modes
au configuration mode