User Manual

Chapter 4 - Operation and Administration Using the CLI Managing AUs
4Motion 465 System Manual
4.5 Managing AUs
Up to seven AU objects can be created and configured, corresponding to the AU
cards that can be installed in slots 1-4, 7-9 of the shelf.
1 Enable the AU configuration mode for the selected AU (refer to Section 4.5.1)
2 You can now execute any of the following tasks:
» Configure one or more of the parameters tables of the AU (refer to
Section 4.5.2)
» Restore the default values of parameters in one or more of the parameters
tables of the AU (refer to Section 4.5.3)
3 Terminate the AU configuration mode (refer to Section 4.5.4)
In addition, you can, at any time, display configuration and status information for
each of the parameters tables of the AU (refer to Section 4.5.6) or delete an
existing AU object (refer to Section 4.3.10.11.5).
4.5.1 Enabling the AU Configuration Mode\Creating
an AU Object
To configure the parameters of an AU, first enable the AU configuration mode for
the specific AU. Run the following command to enable the AU configuration mode.
You can also use this command to create a new AU object. A new AU object is
created with default values for all parameters.
npu (config)# au <(1 to 4 StepSize 1) | (7 to 9 StepSize 1)>
Specify the slot ID of the AU to be configured/created. See Figure 4-1 for slot
assignment in the shelf.
For example, to configure the AU in slot# 1, run the following command:
npu (config)# au 1
NOTE
In Release 2.0 up to 3 AUs may be used for service provisioning.
To configure an AU: