Chapter 4 - Operation and Administration Using the CLI NPU Configuration
4Motion 458 System Manual
After you run this command, the alarm that you had raised is cleared.
4.3.14.6 Displaying Configuration Information for Dry-contact
Input/Output Alarms
To display configuration information for dry-contact input/output alarms, run the
following command:
npu# show dry-contact {IN | OUT} [<alarm_num>]
If you want to display configuration information for input or output alarms,
specify IN or OUT. You can also specify the pin number if you want to view
configuration information for particular pin used for connecting an external device
to the 4Motion unit.
NOTENOTE
For more information about raising a dry contact ouput alarm, refer to
“Raising Dry-contact
Output Alarms” on page 456
.
Command
Syntax
npu(config)# no dry-contact OUT <alarm_num (1-3)>
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<alarm_num
(1-3)>
Indicates the alarm number of
the dry contact output alarm
alarm that is to be disabled.
For more information about
the pin numbers that
correspond to the alarm
number, refer
Table 4-26.
Mandatory N/A 1-3
Command
Modes
Global configuration mode