Chapter 4 - Operation and Administration Using the CLI NPU Configuration
4Motion 457 System Manual
Refer Figure 4-3 for a diagrammatic representation of the 25-pin micro D-Type
ALRM-IN/OUT connector and the numbers assigned to each pin.
4.3.14.5.2 Clearing Dry-contact Output Alarms
After the system returns to its normal state, run the following command to clear
the dry-contact output alarm that you had raised:
npu(config)# no dry-contact OUT <alarm_num (1-3)>
NOTE
After you have raised an alarm, clear this alarm when the system state returns to its normal
condition. For information, refer to,
“Clearing Dry-contact Output Alarms” on page 457.
For more information about displaying configuration information about a dry contact output alarm,
refer to
“Displaying Configuration Information for Dry-contact Input/Output
Alarms” on page 458
.
Command
Syntax
npu(config)# dry-contact OUT <alarm_num (1-3)> alarm <alarm name >
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<alarm_num
(1-3)>
Indicates the alarm number of
the dry contact output alarm
that is to be configured. This
alarm number corresponds to
a pin on the 25-pin micro
D-Type jack .
For more information about
pin numbers that correspond
to the alarm number, refer
Table 4-26.
Mandatory N/A 1-3
alarm <alarm
name>
Indicates the name of the
dry-contact alarm to be
raised.
Mandatory N/A Up to 256
characters
Command
Modes
Global configuration mode