User Manual

Chapter 4 - Operation and Administration Using the CLI Using the Command Line Interface for 4Motion System
4Motion 115 System Manual
“Managing Users and Privileges” on page 122
4.1.1 Accessing the CLI
You can access the CLI, locally, via an ANSI ASCII terminal or PC that is
connected via the DATA port of the NPU. You can also use Telnet/SSH to remotely
access the CLI.
This section describes the procedures for:
“Accessing the CLI from a Local Terminal” on page 115
“Accessing the CLI From a Remote Terminal” on page 116
4.1.1.1 Accessing the CLI from a Local Terminal
1 Use the MON cable to connect the MON connector of the NPU to the COM port
of your ASCII ANSI terminal or PC. The COM port connector of the Monitor
cable is a 3-pin to 9-pin D-type plug.
2 Run a terminal emulation program, such as HyperTerminal™.
3 Set the communication parameters listed in the following table:
4 The login prompt is displayed. (Press Enter if the login prompt is not
displayed.) Enter your login ID and password to log in to the CLI.
To access the CLI via the MON connector:
Table 4-1: COM Port Configuration
Parameter Value
Baud rate 115200
Data bits 8
Stop bits 1
Parity None
Flow control Xon/Xoff
Port Connected COM port