User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 573 System Manual
4.8.6.5.4 Displaying Configuration Information for Power Control Open Loop
Correction Policy Parameters
To display configuration for the Power Control Open Loop Correction Policy
parameters, run the following command:
npu# show pwrctrl-olpolicy bs [<(1 to 16777215 StepSize 1)
Specify the BS ID if you want to display configuration for a particular BS. For
example, to display the Power Control Open Loop Correction Policy parameters of
BS 66053, run the following command:
npu# show pwrctrl-olpolicy bs 66053
Do not specify this parameter if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show pwrctrl-olpolicy bs
Command
Syntax
npu# show pwrctrl-olpolicy bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display the Open Loop
Correction Policy parameters
of a specific BS. Do not
specify a value for this
parameter if you want to
display the Open Loop
Correction Policy parameters
of all BSs.
Optional N/A 1-16777215