User Manual

Chapter 4 - Operation and Administration Using the CLI Managing ODUs
4Motion 490 System Manual
4.6.1.3 Restoring Default Values for ODU Configuration Parameters
After enabling the ODU parameters configuration mode you can restore the
default values for parameters in the following parameters tables:
General (refer to Section 4.6.1.3.1)
Reserved (refer to Section 4.6.1.3.2)
4.6.1.3.1 Restoring the Default Values of General Parameters
To restore one or all of the general parameters to their default value (excluding the
mandatory required-odu-type parameter), run the following command:
npu(config-odu-params-1)# no odu-general [heater-existence]
[external-cavity-filter-existence]
You can restore only one parameter to its default value by specifying only that
parameter. For example, to restore only the heater-existence to the default value
(FALSE), run the following command:
npu(config-odu-params-1)# no odu-general heater-existence
The parameter will be restored to its default value, while the other parameters will
remain unchanged.
To restore all general parameters to their default value, run the following
command:
npu(config-odu-params-1)# no odu-general
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[reserved-N <string
(32)>] (N=1-9)
Reserved parameter number
N
Optional null (an
empty
string)
A string of 32
printable
characters.
Command
Modes
odu-params configuration mode