User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 563 System Manual
npu(config-bs-66053-pwrctrl)# no requiredcnr [ack] [cqi] [cdma] [qpsk-1by2]
[qpsk-3by4] [qam16-1by2] [qam16-3by4] [qam64-1by2] [qam64-2by3]
[qam64-3by4] [qam64-5by6]
You can restore only some parameters to their default values by specifying only
those parameter. For example, to restore only the ack and cqi parameters to the
default values, run the following command:
npu(config-bs-66053-pwrctrl)# no requiredcnr ack cqi
These parameters will be restored to their default value, while the other
parameters will remain unchanged.
To restore all Required C/N Levels parameters to their default value, run the
following command:
npu(config-bs-66053-pwrctrl)# no requiredcnr
4.8.6.3.4 Restoring the Default Values of Power Control Open Loop Correction
Policy Parameters
To restore some or all of the Open Loop Correction Policy parameters to their
default values, run the following command:
npu(config-bs-66053-pwrctrl)# no olpolicy [positivecoefficient]
[negativecoefficient] [max-positivecorrection] [max-negativecorrection]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the positivecoefficient and
negativecoefficient parameters to the default values, run the following command:
NOTE
Refer to Section 4.8.6.2.3 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053-pwrctrl)# no requiredcnr [ack ] [cqi ] [cdma ]
[qpsk-1by2 ] [qpsk-3by4 ] [qam16-1by2 ] [qam16-3by4 ] [qam64-1by2
] [qam64-2by3 ] [qam64-3by4 ] [qam64-5by6 ]
Privilege
Level
10
Command
Modes
bs power control configuration mode