Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 558 System Manual
4.8.6.2.7 Configuring the Power Control Closed Loop - MS in Network Entry
Correction Policy Parameters
To configure the Closed Loop - MS in Network Entry Correction Policy parameters,
run the following command:
npu(config-bs-66053-pwrctrl)# clne [positivecoefficient <(0 to 1 StepSize 0.05)>]
[negativecoefficient <(0 to 1 StepSize 0.05)>] [max-positivecorrection <(0 to 20
StepSize 0.1)>] [max-negativecorrection <(0 to 20 StepSize 0.1)>]
Command
Syntax
npu(config-bs-66053-pwrctrl)# clunstable [positivecoefficient <(0
to 1 StepSize 0.05)> ] [negativecoefficient <(0 to 1 StepSize
0.05)> ] [max-positivecorrection <(0 to 20 StepSize 0.1)>
][max-negativecorrection <(0 to 20 StepSize 0.1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[positivecoefficient
<(0 to 1 StepSize
0.05)> ]
Correction coefficient for
problematic MS in a closed
loop when giving positive
corrections
Optional 0.8 0 to 1 in steps
of 0.05
[negativecoefficien
t <(0 to 1 StepSize
0.05)> ]
Correction coefficient for
problematic MS in a closed
loop when giving negative
corrections
Optional 0.7 0 to 1 in steps
of 0.05
[max-positivecorre
ction <(0 to 20
StepSize 0.1)> ]
Maximum positive power
correction (in dB) for
problematic MS in a closed
loop
Optional 3 0 to 20 in steps
of 0.1
[max-negativecorr
ection <(0 to 20
StepSize 0.1)> ]
Maximum negative power
correction (in dB) for
problematic MS in a closed
loop
Optional 8 0 to 20 in steps
of 0.1
Command
Modes
bs power control configuration mode