User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 550 System Manual
4.8.6.2 Configuring Power Control Parameters
After enabling the Power Control configuration mode you can configure the
following parameters tables:
Target Noise and Interference Level (refer to Section 4.8.6.2.1)
Maximum EIRP (refer to Section 4.8.6.2.2)
Required C/N Level (refer to Section 4.8.6.2.3)
Open Loop Correction Policy (refer to Section 4.8.6.2.4)
Open Loop Correction Range (refer to Section 4.8.6.2.5)
Closed Loop - Unstable MS (refer to Section 4.8.6.2.6)
Closed Loop - MS in Network Entry (refer to Section 4.8.6.2.7)
Closed Loop Correction Range (refer to Section 4.8.6.2.8)
4.8.6.2.1 Configuring Power Control Target Noise and Interference Level
Parameters
The Target Noise and Interference Level table enables defining the target limits for
various noise and interference levels.
To configure the Target Noise and Interference Levels, run the following command:
npu(config-bs-66053-pwrctrl)# nilevels [cqi-ack-ranging <(-150 to -22.5
StepSize 0.5)>] [pusc <(-150 to -22.5 StepSize 0.5)>]
Privilege
Level
10
Command
Modes
bs configuration mode
IMPORTANT
After completing the Power Control configuration,do not forget to execute the apply command
before exiting the Power Control configuration mode:
npu(config-bs-66053-pwrctrl)# apply