User Manual
Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 526 System Manual
To restore one or several BS Service parameters do their default value, run the
following command:
npu(config-bs-66053-service-video)# no def [max-dl-rtx ]
[max-ul-rtx ] [max-subburst ] [trgt-err-rate ]
You can restore one or several parameters to the default value(s) by specifying
only those parameter. For example, to restore only the max-dl-rtx and max-ul-rtx
parameters to their default values, run the following command:
npu(config-bs-66053-service-video)# no def max-dl-rtx max-ul-rtx
The max-dl-rtx and max-ul-rtx parameters will be restored to their default values,
while all other parameters will remain unchanged.
To restore all parameters to their default value, run the following command:
npu(config-bs-66053-service-video)# no def
4.8.4.4 Terminating the BS Service Configuration Mode
Run the following command to terminate the BS Service configuration mode:
npu(config-bs-66053-service-video)# exit
NOTE
Refer to Section 4.8.4.2 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053-service-video)# no def [max-dl-rtx ]
[max-ul-rtx ] [max-subburst ] [trgt-err-rate ]
Privilege
Level
10
Command
Modes
bs service configuration mode
IMPORTANT
Do not forget to execute the apply command before terminating the
BS Service configuration mode:
npu(config-bs-66053-service-video)# apply