User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 677 System Manual
4.8.19.5.8 Displaying Configuration Information for Airframe Uplink Feedback
Zone Parameters
To display configuration for the Airframe Uplink Feedback Zone parameters, run
the following command:
npu# show airframe-ulfeedbackzone bs [<(1 to 16777215 StepSize 1)>]
Specify the BS ID if you want to display configuration for a particular BS. For
example, to display the Airframe Uplink Feedback Zone parameters of BS 66503,
run the following command:
npu# show airframe-ulfeedbackzone bs 66053
Do not specify the BS ID if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show airframe-ulfeedbackzone bs
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display the Airframe Receive
parameters of a specific BS.
Do not specify a value for this
parameter if you want to
display the Airframe Receive
parameters of all BSs.
Optional N/A 1-16777215
Display
Format
(for each
existing
Neighbour
BS in each
of the
existing BSs
if requested
for all)
BSIDLSB :<value>
AdminStatusChannel1 :<value>
AdminStatusChannel2 :<value>
AdminStatusChannel3 :<value>
AdminStatusChannel4 :<value>
Command
Modes
Global command mode