4.8.19.3.9 Restoring the Default Values of Airframe Uplink Data Zone Parameters
To restore one or all of the Airframe Uplink Data Zone parameters to their default
values, run the following command:
npu(config-bs-66053-airframe)# no uldatazone [startallocation]
[subchannels-number]
You can restore only one or several parameters to the default values by specifying
only those parameters. For example, to restore only the startallocation parameters
to the default value, run the following command:
npu(config-bs-66053-airframe)# no uldatazone startallocation
This parameter will be restored to the default values, while the other parameters
will remain unchanged.
To restore all parameters to their default value, run the following command:
npu(config-bs-66053-airframe)# no uldatazone
4.8.19.3.10 Restoring the Default Values of Airframe Dynamic Permutation
Parameters
To restore one or all of the Airframe Dynamic Permutation parameters to their
default values, run the following command:
Privilege
Level
10
Command
Modes
bs airframe configuration mode
NOTE
Refer to Section 4.8.19.2.10 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053-airframe)# no uldatazone [startallocation ]
[subchannels-number ]
Privilege
Level
10
Command
Modes
bs airframe configuration mode