4.8.19.3.5 Restoring the Default Values of Airframe Linear Delay Parameters
To restore one or all of the Airframe Linear Delay parameters to their default
values, run the following command:
npu(config-bs-66053-airframe)# no lineardelay [channel-1] [channel-2]
[channel-3] [channel-4]
You can restore only one or several parameters to the default values by specifying
only those parameters. For example, to restore only the channel-1 and channel-2
parameters to the default value, run the following command:
npu(config-bs-66053-airframe)# no lineardelay channel-1 channel-2
These parameters will be restored to their default values, while the other
parameters will remain unchanged.
To restore all parameters to their default value, run the following command:
npu(config-bs-66053-airframe)# no lineardelay
NOTE
Refer to Section 4.8.19.2.4 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053-airframe)# no cyclicdelay [channel-1 ] [channel-2
] [channel-3 ] [channel-4 ]
Privilege
Level
10
Command
Modes
bs airframe configuration mode
NOTE
Refer to Section 4.8.19.2.5 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053-airframe)# no lineardelay [channel-1 ] [channel-2
] [channel-3 ] [channel-4 ]
Privilege
Level
10