4.8.16.2 Restoring the Default Values of DCD Parameters
To restore the default values of some or all of the DCD parameters, run the
following command:
npu(config-bs-66053)# no dcd [interval] [transition]
You can restore only one parameter to the default values by specifying only that
parameter. For example, to restore only the interval parameter to the default
value, run the following command:
npu(config-bs-66053)# no dcd interval
This parameter will be restored to its default value, while the other parameter will
remain unchanged.
To restore all DCD parameters to their default value, run the following command:
npu(config-bs-66053)# no dcd
Command
Modes
bs configuration mode
IMPORTANT
When creating a new BS, at least one of the DCD parameters must be configured explicitly (even if
configured to the default value).
NOTE
Refer to Section 4.8.16.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no dcd [interval ] [transition ]
Privilege
Level
10
Command
Modes
bs configuration mode