Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 631 System Manual
4.8.15.2 Restoring the Default Values of UCD Parameters
To restore the default values of some or all of the UCD parameters, run the
following command:
npu(config-bs-66053)# no ucd [interval] [transition]
You can restore only one parameter to the default values by specifying only that
parameters. For example, to restore only the interval parameter to the default
value, run the following command:
npu(config-bs-66053)# no ucd interval
This parameter will be restored to its default value, while the other parameter will
remain unchanged.
To restore all UCD parameters to their default value, run the following command:
npu(config-bs-66053)# no ucd
[transition <(20 to
1000 StepSize 1)> ]
The number of frames
from the end of the frame
carrying the Uplink
Channel Descriptor
message that the BS
should wait after repeating
an Uplink Channel
Descriptor message with
an increment of the
configuration change
count before issuing a
UL-MAP message
referring to
Uplink_Burst_Profiles
Optional 100 20 - 1000
Command
Modes
bs configuration mode
IMPORTANT
When creating a new BS, at least one of the UCD parameters must be configured explicitly (even if
configured to the default value).
NOTE
Refer to Section 4.8.15.1 for a description and default values of these parameters.