User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 614 System Manual
4.8.14.2.3 Configuring Trigger Setup Parameters
To configure the Neighbor BS Trigger Setup parameters, run the following
command:
npu(config-bs-66053-nbr-68000)# triggersetup [hysteresismargin <(0 to 255
StepSize 1)>] [timetotrigger <(0 to 255 StepSize 1)>] [avgduration-rssi <(0 to 255
StepSize 1)>] [avgduration-cinr <(0 to 255 StepSize 1)>] [avgduration-rtd <(0 to
255 StepSize 1)>]
The configured values should be the same as those defined for the applicable
Trigger Setup parameters (see Section 4.8.10.3) in the neighbor BS.
qam64-1by2 <(-20
to 50 StepSize 1)> ]
The C/N in dB required for
transmitting using 64QAM 1/2,
reported by the Neighbour BS to
the MS for power control
purposes.
Optional 23 -20 to 50
[qam64-2by3 <(-20
to 50 StepSize 1)> ]
The C/N in dB required for
transmitting using 64QAM 2/3,
reported by the Neighbour BS to
the MS for power control
purposes.
Optional 23 -20 to 50
[qam64-3by4 <(-20
to 50 StepSize 1)> ]
The C/N in dB required for
transmitting using 64QAM 3/4,
reported by the Neighbour BS to
the MS for power control
purposes.
Optional 23 -20 to 50
[qam64-5by6 <(-20
to 50 StepSize 1)> ]
he C/N in dB required for
transmitting using 64QAM 5/6,
reported by the Neighbour BS to
the MS for power control
purposes.
Optional 23 -20 to 50
Command
Modes
bs neighbour bs configuration mode
IMPORTANT