User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 608 System Manual
4.8.14.2 Configuring Neighbor BS Parameters
After enabling the Neighbor BS configuration mode you can configure the
following parameters tables:
General (refer to Section 4.8.14.2.1)
Required C/N Level (refer to Section 4.8.14.2.2)
Trigger Setup (refer to Section 4.8.14.2.3)
Triggers (refer to Section 4.8.14.2.4)
4.8.14.2.1 Configuring General Neighbor BS Parameters
The General Neighbor BS Parameters table enables defining the general
parameters of the Neighbor BS.
To configure the General Neighbor BS parameters, run the following command:
npu(config-bs-66053-nbr-68000)# general [syncind {unsynchronized |
timeSynchronized | timeAndFrequencySynchronized}] [eirp <(-128 to 127
StepSize 1)>] [srvcsupport <hex-string>] [bw {fiveMHz | tenMHz | sevenMHz}]
[feedbackzone-permbase <(0 to 69 StepSize 1)>] [ucd-configchangecount <(0 to
255 StepSize 1)>] [dcd-configchangecount <(0 to 255 StepSize 1)>] [eirx-pir-max
<(-140 to -40 StepSize 1)>] [frequency <(2302.5 to 2357.5 StepSize 0.125) |
(2498.5 to 2687.5 StepSize 0.125) | (3402.5 to 3597.5 StepSize 0.125) | (3602.5
to 3797.5 StepSize 0.125)>] [restartcount <(0 to 255 StepSize 1)>] [preamble-idx
<(0 to 113 StepSize 1)>]
IMPORTANT
After completing the Neighbour BS configuration,do not forget to execute the apply command
before exiting the Neighbour BS configuration mode:
npu(config-bs-66053-nbr-68000)# apply
IMPORTANT
When creating a new Neighbour BS, all mandatory Neighbour BS General parameters must be
configured.