User Manual
Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 600 System Manual
4.8.12.2 Restoring the Default Values of Handover Negotiation at
SBS Parameters
To restore some or all of the Handover Negotiation at SBS parameters to their
default values, run the following command:
npu(config-bs-66053)# no honegotiation-sbs [selectcoefficient] [max-tbs]
[min-actiontime] [max-actiontime]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the max-tbs parameter to the
default value, run the following command:
npu(config-bs-66053)# no honegotiation-sbs max-tbs
This parameter will be restored to its default value, while the other parameters
will remain unchanged.
To restore all Handover Negotiation at SBS parameters to their default value, run
the following command:
npu(config-bs-66053)# no honegotiation-sbs
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[selectcoefficient <(0
to 10 StepSize 0.1)> ]
The coefficient for
selection of Target BSs for
MOB_BSHO-RSP
Optional 0.3 0 to 10 in
steps of 0.1
[max-tbs <(0 to 255
StepSize 1)> ]
The naximum number of
Target BSs to which to
send HO-REQ message
through the backbone.
Optional 255 0 - 255
[min-actiontime <(0 to
255 StepSize 1)> ]
The minimum acceptable
action time in the Serving
BS (in frames)
Optional 1 0 - 255
[max-actiontime <(0 to
255 StepSize 1)> ]
The maximum acceptable
action time in the Serving
BS (in frames)
Optional 255 0 - 255
Command
Modes
bs configuration mode