4.8.11.2 Restoring the Default Values of Scan Negotiation
Parameters
To restore some or all of the Scan Negotiation parameters to their default values,
run the following command:
npu(config-bs-66053)# no scanning [max-attempts] [interval]
[enable-autoaccept] [enable-modify][min-interval] [max-duration]
[min-degradationfactor] [honegotiation-sbs]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the max-attempts parameter to the
default value, run the following command:
npu(config-bs-66053)# no scanning max-attempts
This parameter will be restored to its default value, while the other parameters
will remain unchanged.
To restore all Scan Negotiation parameters to their default value, run the following
command:
npu(config-bs-66053)# no scanning
4.8.11.3 Displaying Configuration Information for Scan Negotiation
Parameters
To display configuration information for Scan Negotiation parameters, run the
following command:
npu# show scanning bs [<(1 to 16777215 StepSize 1)
NOTE
Refer to Section 4.8.11.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no scanning [max-attempts ] [interval ]
[enable-autoaccept ] [enable-modify ][min-interval ] [max-duration
] [min-degradationfactor ] [honegotiation-sbs ]
Privilege
Level
10
Command
Modes
bs configuration mode