User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 596 System Manual
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[max-attempts <(0 to
255 StepSize 1)> ]
The maximum allowed
number of consecutive
MOB_SCN-REQs .
Optional 10 0 - 255
[interval <(0 to 100
StepSize 0.1)> ]
The measuring interval for
counting
MOB_SCN-REQs abuse.
Optional 1 0 to 100
secs in
steps of 0.1
[enable-autoaccept
{TRUE | FALSE} ]
Determine whether all
scan profiles requested by
MSs will be accepted
automatically.
Note: If TRUE all scan
request will be
automatically accepted.
Optional TRUE
TRUE
FALSE
[enable-modify {TRUE
| FALSE} ]
Determines whether the
BS will modify unfeasible
scan profiles requested by
MSs.
Note: If TRUE the BS will
modify unfeasible scan
profile requests and if
FALSE the BS will deny
the requests.
Optional TRUE
TRUE
FALSE
[min-interval <(2 to
255 StepSize 1)> ]
The minimum interleaving
interval permitted to the
MS in the scan profile (in
frames)
Optional 2 0 - 255
[max-duration <(0 to
255 StepSize 1)> ]
The maximum duration of
a scan permitted to the
MS in the scan profile (in
frames).
Optional 255 0 - 255
[min-degradationfacto
r <(0 to 1 StepSize
0.1)> ]
The minimum bandwidth
degradation factor allowed
in the scan profile
Optional 0 0 to 1 in
steps of 0.1
[honegotiation-sbs
<(0 to 255 StepSize
1)> ]
The minimum value (in
frames) for the start frame
in the scan profile.
Optional 0 0 - 255
Command
Modes
bs configuration mode