User Manual
Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 594 System Manual
Specify the BS ID if you want to display configuration for a particular BS. For
example, to display the Trigger Setup parameters of BS 66053, run the following
command:
npu# show triggersetup bs 66053
Do not specify this parameter if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show triggersetup bs
Command
Syntax
npu# show triggersetup bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display Trigger Setup
parameters of a specific BS.
Do not specify a value for this
parameter if you want to
display Trigger Setup
parameters of all BSs.
Optional N/A 1-16777215
Display
Format
(for each
existing BS
if requested
for all BSs)
BSIDLSB :<value>
HysteresisMargin(dB) :<value>
TimetoTrigger(msec) :<value>
AverageDurationofDefaultRSSI(msec) :<value>
AverageDurationofDefaultCINR(msec) :<value>
AverageDurationofDefaultRTD(msec) :<value>
Command
Modes
Global command mode